grandMA3 User Manual Publication

/CueOnly Option Keyword

grandMA3 User Manual » Command Syntax and Keywords » Option Keywords » /CueOnly
Version 2.1

To enter the /CueOnly option keyword in the command line, use one of the options:

  • Type /CueOnly
  • Type the shortcuts /Co or /Cu

Description

The /CueOnly option keyword blocks tracked values in the next cue or cue part to preserve the previous look on stage. 

For more information see Store Cues and Store Settings and Store Preferences

Syntax

[Function] (Sequence ["Sequence_Name" or Sequence_Number]) Cue ["Cue_Name" or Cue_Number] /CueOnly ["Value"]

General Keywords

General keywords that use the /CueOnly option keyword:

Values

The /CueOnly option keyword uses these values:

  • DimmerOnly – uses the Dimmer Cue Only and releases the recently stored dimmer attributes in the next cue. 
  • DimmerOnlyDefaultNew – uses the Dimmer Cue Only and sets recently stored dimmer attributes to the default value in the next cue. 
  • Off – does not use CueOnly 
  • On –  uses CueOnly
  • OnDefaultNew – uses Cue Only and sets new attributes within the sequence to the default value in the next cue.

Examples

  • To store the current programmer values in cue 8 and to preserve the previous look in the following cue after cue 8, type:
User name[Fixture]>Store Cue 8 /CueOnly 


  • To store the current programmer values in cue 6 and release the recently stored dimmer values in the next cue, type:
User name[Fixture]>Store Cue 6 /CueOnly "DimmerOnly"


  • To store the current programmer values in cue 5 and set the dimmer attributes to default values in the next cue, type:
User name[Fixture]>Store Cue 5 /CueOnly "DimmerOnlyDefaultNew"