dot2
Version 1.9

StoreLook Command

This page describes the syntax and how to use the StoreLook command.

To go to the StoreLook command, press and hold ma and Store on the console.

Description

With the StoreLook command, you can store your actual look as a cue on an executor.

The StoreLook command stores all dimmer values from all fixtures in the show.
If the dimmer value is bigger than 0 it stores additional all further attributes.
If the dimmer value is 0, it stores only the dimmer value because there is no further actual output of the fixture.

A cue stored with the StoreLook command is automatically set to protected. Previous tracked values does not affect a cue stored with StoreLook. For more information about protected, refer to Cues View or How to work with cues. For more information about tracking, refer to What is Tracking?

Syntax

Store the actual look from all fixtures in the show.

StoreLook

Example

Let´s assume you will store the actual look from all fixtures in the show as a cue on executor 1.

Figure 1: Fixtures Sheet before store with StoreLook
Figure 2: Fixtures Sheet after store with StoreLook

Press ma + Store (=StoreLook) and the respective executor button go .

All dimmer values are stored.
All attributes are stored if the dimmer value was bigger than 0.

For more information about the colors in the fixtures sheet, refer to System Colors - Values.