Release Notes - Version 3.5.0.6
Important Information for Updating
Fixed Bugs and Improved Functionality
You will find the latest system requirements for several products on www.malighting.com
Important Information for Updating
Update dimMA system:
If you would like to update the dimMA system from any version below 7.x, contact your MA dealer or MA directly for any update information. If you use grandMA2 along with dimMA solutions, get in touch with us. A console update requires an MA NDP (= Network Dimmer Processor) update and vice versa. We are happy to assist you.
Update grandMA2 onPC and MA 3D:
The current versions of grandMA onPC and MA 3D require at least Windows® 7. Microsoft® .NET Framework (4.0) will be installed on your computer.
Update MA VPU
If you would like to update the MA VPU basic or the MA VPU light from any version to v3.2 or higher, at least one screen and one mouse has to be connected to the MA VPU.
Update MA Network Switch
If you would like to update the MA Network Switch in v3.1 or v3.2 to v3.3 or a subsequent version, execute the display reset after the update has been installed. As soon as Booting is displayed on the display of the MA Network Switch after the update:
- Disconnect the power.
- Press and hold the yellow menu button on the left side of the display.
- While holding the button power up the MA Network Switch again.
- As soon as Booting appears on the display of the MA Network Switch release the button.
To execute a fallback on v3.3 or a subsequent version in v3.1 or v3.2, proceed in the same manner.
Bugfix Version 3.5.0.6
Fixed Bugs and Improved Functionality
Description |
---|
Improved - Images for wheel slots have to be inside the gobo folder on the drive. |
Mode2 on grandMA3
Description |
---|
grandMA3 devices running in Mode2 experienced sudden GUI freezes resulting in the console still working, but the GUI not responding. This bug is fixed. grandMA3 devices running in Mode2 should not freeze any longer. |
Bugfix Version 3.5.0.3
Fixed Bugs and Improved Functionality
Description |
---|
Fixed - Crash when pressing Set or Please while having the color picker open. |
Fixed - Color values are changed when using Color Picker and Previous, Next, Up and Down. |
Fixed - Color Picker blocks the command line. |
Fixed - Crash on FindBestFocus. |
Fixed - Wrong description for RDM parameter Display_Level in the RDM menu. |
Fixed - Programmer knocks in additional values when editing a cue of the curently running playback. |
Fixed - Open Show Folder link shows correct version number. |
Fixed - Dimmer visualization of VPU Layer fixtures in the layout view. |
Improved - Position of Select Effect Attribute pop-up in Mode2. |
Improved - Layout view frame drawing in Mode2. |
grandMA2 Release Version 3.5.0.2
Fixed Bugs and Improved Functionality
Description |
---|
Fixed - Locked sequences still allow to edit the sequence info. |
Fixed - Desk status shows wrong amount of assigned playbacks. |
Fixed - Smart view does not show channel sets of attributes controlled by mode channels, if mode channel is set to "Default Link" in the programmer. |
Fixed - EnableVideoCodes keyword has a faulty shortcut. |
Fixed - CMDHelp lists wrong abbreviation of Info keyword. |
Improved - Assign dialog has no screen selector. |
Fixed - Crash when updating a sequence. |
Fixed - GoBack and <<< as button function for an assigned single line macro executes the macro twice. |
Fixed - Record on an empty macro is not working. |
Fixed - Appearance dialog can not closed by pressing the Please button. |
Fixed - Crash when using Align. |
Fixed - Lasso selection of timecode events works not reliable. |
Fixed - Loading a dot2 show on grandMA2 results in only 9 useable DMX universes. |
Fixed - Crash when copying timecode events between 2 tracks. |
Fixed - Crash when editing a range of cells, where the first cell is uneditable. |
MA web remote
Description |
---|
Added - All presets can be used by the web remote. |
Fixed - Web remote freezes on cancelling the store pop up. |
Added - Clear and Store buttons have been added to the preset pool page. |
MA xPort Nodes
Description |
---|
Fixed - DMX In can fail if external source is already sending DMX while the xPort is booting. |
MA onPC
Description |
---|
Fixed - onPC keys stay illuminated when pressed by keyboard shortcuts while onPC runs in multi screen mode. |
Fixed - onPC crashes when starting a certain executor. |
Mode2 on grandMA3
Description |
---|
Fixed - Unplug the network cable does not write message center notification |
Fixed - Edit + Macro button executes the macro |
Fixed - Eject an USB stick does not remove the USB stick tab in the backup menu. |
Fixed - Function pop up in the assign menu is not fully readable. |
Appendix
- Off Executor 1 thru 100 - This switches off all faders of current page.
- Off Executor 101 thru 240 - This switches off all buttons of current page.
- Off Executor 1 thru 100 Page Thru - $faderpage - This switches off all faders of all pages except the current page.
- Off Executor 101 thru 240 Page Thru - $buttonpage - This switches off all buttons of all pages except current the current page.
- Go Exec "exec name" - starts executor with specified name on current page.
- Go Exec "exec number" - starts executor with specified number on current page.
- Go Exec "*"."exec name" - starts executor with specified name on all pages.
- Go Exec "*"."exec number" - starts executor with specified number on all pages.
- Go Exec "page name"."exec name" - starts executor with specified name on specified page.
- Go Exec "page name"."exec number" - starts executor with specified number on specified page.
- Go Exec "page number"."exec name" - starts executor with specified name on specified page.
- Go Exec "page number"."exec number" - starts executor with specified number on specified page.
Known Limitations
- Pan/Tilt offsets should not be set to higher values than the fixture type provides due to its physical limitations. Setting values out of the physical range can affect the correct visualization in the stage view of the grandMA2 and MA 3D.
- Active dimmer values given from the desk do not cause the MA VPU to send its merge defaults for the color attribute. This may cause an unexpected output if only the dimmer of a fixture is controlled by the desk. To avoid this and to gain full control, just set the color attribute actively in the programmer. Or store the color information to an executor which is set to a higher priority than the pixel mapper output. Do not forget to switch off this executor if the output of the pixel mapper is to be active again.
- If using the Set button in the web remote, the command line default will be changed to MATricks.
- At the initial start after the installation or the update of the MA VPU application, the end user license agreement is shown. The MA VPU application will not start, until the end user license agreement is confirmed. If you are using a VPU Plus, the end user license agreement is shown at the internal touch display. If you are using a MA VPU basic or MA VPU light, the end user license agreement is shown at the first external DVI-output - so please make sure you have a display and a mouse attached to the MA VPU basic or MA VPU light.
- Ma-Net1 is not supported for MA 2Ports Version 1.77 or higher.
- MA onPC command wing DMX input is supported for the ports "DMX In" and "DMX out A" only. The port "DMX out B" can only be used as DMX out!
- Before loading show files stored with grandMA2 v2.7.x the first time with grandMA2 v2.9.x, attribute Colormix4 and 5 and Colordim4 and 5 of self-made fixture types have to be manually adjusted to fulfill the color specification. Amber has to be Colormix 4 invert or Colordim 4 without invert, and White has to be Colormix 5 invert or Colordim 5 without invert. Otherwise, color information of these fixture types will be lost after loading show file with v2.9.
- The feature name for ColorDim/ColorMix has changed into MixColor. Macros using one of these feature names have to be adjusted.
- Known limitation when loading show files stored with v2.8.x for the first time in v2.9
- Special Masters have a new data structure in grandMA2 software.
- All Special Master custom labels will be reset to MA default labels
- Assignment of 100mm faders will be reset to default.
- Macros referring to special masters have to be adjusted and have to use the new naming and numbering of special masters.
- Macros referring to relative values have to be adjusted according to new relative/absolute syntax.
- User profiles exported to USB drives using v2.8 and previous versions have to be manually moved from folder importexport to user_profile folder in order to import these profiles using grandMA2 v2.9 and subsequent versions.
- Special Masters have a new data structure in grandMA2 software.
- MA 4Port Nodes and MA 8Port Nodes have to be updated to v1.0.9 or subsequent versions to be compatible with grandMA2 v2.9. MA 2Port Nodes have to be updated to 1.77 or subsequent versions in order to be compatible to grandMA2 v2.9.
- Channel set labels of fixture types have to be unique to be visible and accessible in calculator. E.g., if channel sets of Attribute Shutter are closed, open, open, open, only one open is visible in the calculator. Changing channel set labels to closed, open, open(2), open(3), results in all channel sets being visible in the calculator.
- Astronomical clock always calculates time according to standard time zone. Additional summer times are not recognized and cannot be adjusted manually when using sunset, dusk, dawn, and sunrise in the agenda.
- Bitmap fixtures can be applied to physical parameters only. Virtual parameters such as a virtual dimmer or XYZ attributes are not supported.