Release Notes Version 3.6.1.1
Important Information for Updating
Fixed Bugs and Improved Functionality
You will find the latest system requirements for several products on www.malighting.com
Important Information for Updating
Update dimMA system:
If you would like to update the dimMA system from any version below 7.x, contact your MA dealer or MA directly for any update information. If you use grandMA2 along with dimMA solutions, get in touch with us. A console update requires an MA NDP (= Network Dimmer Processor) update and vice versa. We are happy to assist you.
Update grandMA2 onPC and MA 3D:
The current versions of grandMA onPC and MA 3D require at least Windows® 7. Microsoft® .NET Framework (4.0) will be installed on your computer.
Update MA VPU
If you would like to update the MA VPU basic or the MA VPU light from any version to v3.2 or higher, at least one screen and one mouse has to be connected to the MA VPU.
Update MA Network Switch
If you would like to update the MA Network Switch in v3.1 or v3.2 to v3.3 or a subsequent version, execute the display reset after the update has been installed. As soon as Booting is displayed on the display of the MA Network Switch after the update:
- Disconnect the power.
- Press and hold the yellow menu button on the left side of the display.
- While holding the button power up the MA Network Switch again.
- As soon as Booting appears on the display of the MA Network Switch release the button.
To execute a fallback on v3.3 or a subsequent version in v3.1 or v3.2, proceed in the same manner.
Release Notes
grandMA2 version 3.6.1.1
New Feature
The latest release of grandMA2 3.6.1.1 rolls out several new features and enhancements that enrich your lighting experience. Read on for a quick introduction and find links to resources that offer more information.
Mode2 in grandMA3 Compact and Compact XT Consoles
The grandMA3 Compact and Compact XT supports Mode2.
To display the X-Keys bar on Compact and Compact XT consoles, press U1 .
As the Compact console has only 1 screen, press U2 to toggle the executor bar.
For more information see Mode2.
Fixed Bugs and Improved Functionality
Description |
---|
Fixed - AutoStomp of higher prioritized playbacks are be ignored when the parameters are released by a lower prioritized playback. |
Fixed - Conditional expressions in macros did not work, if the string had spaces. |
Fixed - Wheel slot thumbnails are not displayed, if the wheel slot has no name. |
Fixed - Moving an executor to a different one did not move the empty executor back to 0. |
Fixed - Pool object IDs higher than 9999 are cropped on external screens. |
Fixed - Console can become unresponsive if empty sequences are part of the show download. |
Fixed - Flipping some multi instance fixtures could crash the console. |
Fixed - Menu Off command does not work with all menus. |
Fixed - Console crashed when leaving the patch & fixture schedule. |
Fixed - When executing Logout and Blackscreen commands in a macro, some parts of the screens are not blacked out. |
Fixed - Desk status window was partly unreadable if the window was at a minimum. |
Fixed - AutoCreate menu can be opened if the user rights forbid the execution of AutoCreate. |
Added - Carallon library 14.5 |
Fixed - Selected layout is not correctly imported on importing a user profile. |
Fixed - Message center did not allow to enable pop ups in the chat category. |
Fixed - Crash when trying to solve thousands of auto create conflicts by keeping ESC pressed. |
Fixed - Crash during show download while a user tried to label a cue. |
Fixed - Exporting a sequence does not export all information. |
Fixed - Cloning from a fixture or a fixture type to the universal fixture type does not work. |
Fixed - Sending DMX via network protocols to several missing unicast receivers results in a non-uniform DMX output. |
Fixed - Oopsing an agenda entry does not remove it again. |
Added - New 2Port version 1.82. DMX output will not be stopped, if the session will ends. |
grandMA2 onPC
Description |
---|
Fixed - Entering setup mode of layout view got encoder bars on screen 1 and screen 2 out of sync. |
Fixed - Unlocking an onPC station with Shift + CAlt + F fails if the onPC is locked before with the Pause key on the PC keyboard. |
Mode2 on grandMA3
Description |
---|
Improved - Program Time / Exec Time hardware block on grandMA3 full-size consoles can be disabled with the option Enable Program Time/Exec Time Hardware Block in the grandMA3 settings menu. |
Improved - Non available xKeys can be hide with the new option Grayed out X-Button Dialogs in the grandMA3 settings menu. |
Fixed - Some fixtures are not recognized via RDM. |
Appendix
- Off Executor 1 thru 100 - This switches off all faders of current page.
- Off Executor 101 thru 240 - This switches off all buttons of current page.
- Off Executor 1 thru 100 Page Thru - $faderpage - This switches off all faders of all pages except the current page.
- Off Executor 101 thru 240 Page Thru - $buttonpage - This switches off all buttons of all pages except current the current page.
- Go Exec "exec name" - starts executor with specified name on current page.
- Go Exec "exec number" - starts executor with specified number on current page.
- Go Exec "*"."exec name" - starts executor with specified name on all pages.
- Go Exec "*"."exec number" - starts executor with specified number on all pages.
- Go Exec "page name"."exec name" - starts executor with specified name on specified page.
- Go Exec "page name"."exec number" - starts executor with specified number on specified page.
- Go Exec "page number"."exec name" - starts executor with specified name on specified page.
- Go Exec "page number"."exec number" - starts executor with specified number on specified page.
Known Limitations
- Screensaver feature is deactivated on Mode2, as the hardware components do not require a screensaver.
- Pan/Tilt offsets should not be set to higher values than the fixture type provides due to its physical limitations. Setting values out of the physical range can affect the correct visualization in the stage view of the grandMA2 and MA 3D.
- Active dimmer values given from the desk do not cause the MA VPU to send its merge defaults for the color attribute. This may cause an unexpected output if only the dimmer of a fixture is controlled by the desk. To avoid this and to gain full control, just set the color attribute actively in the programmer. Or store the color information to an executor which is set to a higher priority than the pixel mapper output. Do not forget to switch off this executor if the output of the pixel mapper is to be active again.
- If using the Set button in the web remote, the command line default will be changed to MATricks.
- At the initial start after the installation or the update of the MA VPU application, the end user license agreement is shown. The MA VPU application will not start, until the end user license agreement is confirmed. If you are using a VPU Plus, the end user license agreement is shown at the internal touch display. If you are using a MA VPU basic or MA VPU light, the end user license agreement is shown at the first external DVI-output - so please make sure you have a display and a mouse attached to the MA VPU basic or MA VPU light.
- Ma-Net1 is not supported for MA 2Ports Version 1.77 or higher.
- MA onPC command wing DMX input is supported for the ports "DMX In" and "DMX out A" only. The port "DMX out B" can only be used as DMX out!
- Before loading show files stored with grandMA2 v2.7.x the first time with grandMA2 v2.9.x, attribute Colormix4 and 5 and Colordim4 and 5 of self-made fixture types have to be manually adjusted to fulfill the color specification. Amber has to be Colormix 4 invert or Colordim 4 without invert, and White has to be Colormix 5 invert or Colordim 5 without invert. Otherwise, color information of these fixture types will be lost after loading show file with v2.9.
- The feature name for ColorDim/ColorMix has changed into MixColor. Macros using one of these feature names have to be adjusted.
- Known limitation when loading show files stored with v2.8.x for the first time in v2.9
- Special Masters have a new data structure in grandMA2 software.
- All Special Master custom labels will be reset to MA default labels
- Assignment of 100mm faders will be reset to default.
- Macros referring to special masters have to be adjusted and have to use the new naming and numbering of special masters.
- Macros referring to relative values have to be adjusted according to new relative/absolute syntax.
- User profiles exported to USB drives using v2.8 and previous versions have to be manually moved from folder importexport to user_profile folder in order to import these profiles using grandMA2 v2.9 and subsequent versions.
- Special Masters have a new data structure in grandMA2 software.
- MA 4Port Nodes and MA 8Port Nodes have to be updated to v1.0.9 or subsequent versions to be compatible with grandMA2 v2.9. MA 2Port Nodes have to be updated to 1.77 or subsequent versions in order to be compatible to grandMA2 v2.9.
- Channel set labels of fixture types have to be unique to be visible and accessible in calculator. E.g., if channel sets of Attribute Shutter are closed, open, open, open, only one open is visible in the calculator. Changing channel set labels to closed, open, open(2), open(3), results in all channel sets being visible in the calculator.
- Astronomical clock always calculates time according to standard time zone. Additional summer times are not recognized and cannot be adjusted manually when using sunset, dusk, dawn, and sunrise in the agenda.
- Bitmap fixtures can be applied to physical parameters only. Virtual parameters such as a virtual dimmer or XYZ attributes are not supported.